| Applications | | Environmental | | River Depth Monitoring |
|
 |
 | River depth monitoring with telemetry gives you upto date knowledge
Battery powered Radcom data loggers are perfect for monitoring River levels.
|
External Pressure (Depth) Monitoring Systems with Telemetry
Clean water or reservoirs can be monitored with submerged pressure sensors connected to any Radcom logger with an external pressure input. Calibration is stored within the logger such that real engineering depth units or are accessible from the data logger (Metres, mBar etc). |
 |
|
 |
| Depth sensors can be supplied with either a quick release coupling (for connection to the outside wall of the tank) or more typically with a plastic cone end to minimise the risk of dirt entering the sensor when the transducer is resting on the floor of the tank. |
|
Various low pressure ranges are availanle:- 0-0.75 Metres head (0-0.075 Bar, ie 75mBar) 0-1.5 Metres head (0-0.15 Bar, ie 150mBar) 0-5 Metres head (0-0.5 Bar) 0-10 Metres head (0-1 Bar) 0-50 Metres head (0-5 Bar)
|
|
|
|
|
|
|
Ultrasonic Level Sensor Monitoring Systems with Telemetry
Alternatively for rivers and less clean water, non-contacting sensors are recommended. Radcom have two options for such non contacting sensors:- 1) Siemens Miltronics "The Probe" Ultrasonic sensor 2) Radcom "SonicSens" Ultrasonic sensor |
|
1) Siemens Miltronics "The Probe" Ultrasonic sensor with Radcom data logger |
|

2) Radcom "SonicSens" Ultrasonic sensor with Radcom data logger |
Download Listing |
One Download |
|
 |
|
| Depth Sensors, (ie External pressure transducers) |
Download Listing |
2 Downloads |
|
 |
|
RAU R01/02/xx SMS x KIT: SonicSens Ultrasonic level monitoring system, including telemetry data logger.
Note an Intrinsically Safe ATEX certified version is also available for Hazardous Area applications such as CSO (Combined Sewer Overflow). RAU R01/02/xx SMS / KIT/ Exi |
 |
|
| RDL 661L/50/ RCI /Probe Exi KIT: Siemens "The Probe" Ultrasonic level monitoring system, including telemetry data logger with Intrinsically Safe approvals, for use in Hazardous Areas (eg CSO). |
|