| Applications | | Potable | | Monitoring Applications | | Domestic Survey Flow Logging |
|
 |
 | Domsetic water usage survey - flow logging
Radcom LoLog data loggers are cost effective solutions to provide Flow data, based on a 15 minute sample period, and can store approximately 6 months of data in a small logger. Special compressed memory storage versions of LoLog data loggers are available for Domestic survey applications giving greater data storage or quicker download times when at site.
 |
|
LoLog data loggers with a single digital flow input are ideal for Domestic water usage survey applications. |
|
"Diurnal" Flow graph, indicating the typical pattern of water usage repeated daily.
Low flow at night with two peaks one in morning, and the other in the evening.
Minimum night line flow above Zero indicates a potential pipe leak. . |
|
 |
 |
|
Radcom LoLog data loggers can be configured to record at up to 1 second sample periods, however in such applications the standard 16, 000 reading memory will be filled or recycled very rapidly.
Most domestic surveys are monitored with a 15 minute sample period between readings. |
| LoLog is available with an integral MSN sensor, such that the logger is simply clipped onto the MSN meter without the need for any wiring. |
|
|
|
|
|
Download Listing |
2 Downloads |
|
 |
|
| RDL 411L (REV 414L): LoLog portable non-telemetry data logger, potted for life. |
 |
|
| RDL 51xL (RDL 50xL): LoLogLL portable non-telemetry data logger, battery replacable. |
|